Size-resolved particle number emissions in Beijing determined from measured particle size distributions
dc.contributor.affiliation | University of Helsinki - Kontkanen, Jenni | |
dc.contributor.affiliation | Tsinghua University - Deng, Chenjuan | |
dc.contributor.affiliation | University of Helsinki - Dada, Lubna | |
dc.contributor.affiliation | Beijing University of Chemical Technology - Zhou, Ying | |
dc.contributor.affiliation | University of Helsinki - Cai, Jing | |
dc.contributor.affiliation | University of Helsinki - Daellenbach, Kaspar R. | |
dc.contributor.affiliation | University of Helsinki - Hakala, Simo | |
dc.contributor.affiliation | University of Helsinki - Kokkonen, Tom. V. | |
dc.contributor.affiliation | Beijing University of Chemical Technology - Lin, Zhuohui | |
dc.contributor.affiliation | Beijing University of Chemical Technology - Liu, Yongchun | |
dc.contributor.affiliation | University of Helsinki - Wang, Yonghong | |
dc.contributor.affiliation | Beijing University of Chemical Technology - Yan, Chao | |
dc.contributor.affiliation | University of Helsinki - Petäjä, Tuukka | |
dc.contributor.affiliation | Tsinghua University - Jiang, Jingkun | |
dc.contributor.affiliation | University of Helsinki - Kulmala, Markku | |
dc.contributor.affiliation | University of Helsinki - Paasonen, Pauli | |
dc.contributor.author | Kontkanen, Jenni | |
dc.contributor.author | Deng, Chenjuan | |
dc.contributor.author | Fu,Yueyun | |
dc.contributor.author | Dada, Lubna | |
dc.contributor.author | Zhou, Ying | |
dc.contributor.author | Cai, Jing | |
dc.contributor.author | Daellenbach, Kaspar R. | |
dc.contributor.author | Hakala, Simo | |
dc.contributor.author | Kokkonen, Tom. V. | |
dc.contributor.author | Lin, Zhuohui | |
dc.contributor.author | Liu, Yongchun | |
dc.contributor.author | Wang, Yonghong | |
dc.contributor.author | Yan, Chao | |
dc.contributor.author | Petäjä, Tuukka | |
dc.contributor.author | Jiang, Jingkun | |
dc.contributor.author | Kulmala, Markku | |
dc.contributor.author | Paasonen, Pauli | |
dc.date.accessioned | 2025-03-24T15:11:23Z | |
dc.date.issued | 2020-08-25 | |
dc.date.issued | 2020-08-25 | |
dc.description | The average daily cycle of size-resolved particle number emissions determined for the measurement station of Beijing University of Chemical Technology, Beijing, China. The average is calculated for January 2018 – March 2019. The details of the particle size distribution measurements and the method used for producing the emissions are presented by Kontkanen et al., Size-resolved particle number emissions in Beijing determined from measured particle size distributions, ACP, 2020. Data file contents: 1st row contains particle diameter (unit:m). 1st column contains time (unit:hour), and the following columns contain particle number emissions (unit: m-2 s-1). For more details, contact: jenni.kontkanen@helsinki.fi | |
dc.identifier | https://doi.org/10.5281/zenodo.3999054 | |
dc.identifier.uri | https://hydatakatalogi-test-24.it.helsinki.fi/handle/123456789/9145 | |
dc.rights | Open | |
dc.rights.license | cc-by-4.0 | |
dc.title | Size-resolved particle number emissions in Beijing determined from measured particle size distributions | |
dc.type | dataset | |
dc.type | dataset |